1.
Heart Rhythm O2 ; 5(3): 182-188, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560377

RESUMO

Background: Recent studies suggest that participation in recreational and even competitive sports is generally safe for patients with implantable cardioverter-defibrillators (ICDs). However, these studies included only patients with implanted transvenous ICD (TV-ICD). Nowadays, subcutaneous ICD (S-ICD) is a safe and effective alternative and is increasingly implanted in younger ICD candidates. Data on the safety of sport participation for patients with implanted S-ICD systems is urgently needed. Objectives: The goal of the study is to quantify the risks (or determine the safety) of sports participation for athletes with an S-ICD, which will guide shared decision making for athletes requiring an ICD and/or wishing to return to sports after implantation. Methods: The SPORT S-ICD (Sports for Patients with Subcutaneous Implantable Cardioverter Defibrillator) study is an international, multicenter, prospective, noninterventional, observational study, designed specifically to collect data on the safety of sports participation among patients with implanted S-ICD systems who regularly engage in sports activities. Results: A total of 450 patients will undergo baseline assessment including baseline characteristics, indication for S-ICD implantation, arrhythmic history, S-ICD data and programming, and data regarding sports activities. LATITUDE Home Monitoring information will be regularly transferred to the study coordinator for analysis. Conclusion: The results of the study will aid in shaping clinical decision making, and if the tested hypothesis will be proven, it will allow the safe continuation of sports for patients with an implanted S-ICD.

2.
Heart Rhythm ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

3.
BJOG ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326282

RESUMO

OBJECTIVE: Data and guidelines are lacking, so implantable cardioverter-defibrillators (ICDs) are often deactivated during labour to prevent inappropriate shocks. This study aimed to ascertain the safety of an activated ICD during labour. DESIGN: An observational study was performed. SETTING: Dutch hospitals. POPULATION OR SAMPLE: A total of 41 childbirths were included of 26 patients who gave birth between February 2009 and November 2018 after receiving an ICD in our tertiary hospital. Five of these childbirths were attended by the research team between December 2018 and August 2020, during which the ICD remained active. METHODS: Groups were made based on ICD status during labour. Patients who gave birth with an activated ICD at least once were stratified to the activated ICD group. Patients' files were checked and patients received a questionnaire about childbirth perceptions and treatment preferences. The differences in ordinal data resulting from the questionnaire were calculated using a chi-square or Fisher's exact test. MAIN OUTCOME MEASURES: Primary outcome was inappropriate ICD therapy and occurrence of ventricular arrhythmias requiring treatment. RESULTS: During the 41 childbirths, no inappropriate shocks or ventricular arrhythmias occurred during labour. All patients in the activated ICD group (n = 13) preferred this setting, while 8 of the 13 patients in the deactivated ICD group preferred activation (p = 0.002). Reasons included avoiding hemodynamic monitoring, magnet placement, or labour induction to facilitate technician availability. CONCLUSIONS: This study shows no evidence that labour and birth in women with an activated ICD are unsafe, as there were no ventricular arrhythmias or inappropriate therapy. In addition, most patients prefer an activated ICD during labour.

5.
EBioMedicine ; 99: 104937, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38118401

RESUMO

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Morte Súbita Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Eletrocardiografia , Redes Neurais de Computação
7.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37712675

RESUMO

AIMS: Left ventricular ejection fraction (LVEF) is suboptimal as a sole marker for predicting sudden cardiac death (SCD). Machine learning (ML) provides new opportunities for personalized predictions using complex, multimodal data. This study aimed to determine if risk stratification for implantable cardioverter-defibrillator (ICD) implantation can be improved by ML models that combine clinical variables with 12-lead electrocardiograms (ECG) time-series features. METHODS AND RESULTS: A multicentre study of 1010 patients (64.9 ± 10.8 years, 26.8% female) with ischaemic, dilated, or non-ischaemic cardiomyopathy, and LVEF ≤ 35% implanted with an ICD between 2007 and 2021 for primary prevention of SCD in two academic hospitals was performed. For each patient, a raw 12-lead, 10-s ECG was obtained within 90 days before ICD implantation, and clinical details were collected. Supervised ML models were trained and validated on a development cohort (n = 550) from Hospital A to predict ICD non-arrhythmic mortality at three-year follow-up (i.e. mortality without prior appropriate ICD-therapy). Model performance was evaluated on an external patient cohort from Hospital B (n = 460). At three-year follow-up, 16.0% of patients had died, with 72.8% meeting criteria for non-arrhythmic mortality. Extreme gradient boosting models identified patients with non-arrhythmic mortality with an area under the receiver operating characteristic curve (AUROC) of 0.90 [95% confidence intervals (CI) 0.80-1.00] during internal validation. In the external cohort, the AUROC was 0.79 (95% CI 0.75-0.84). CONCLUSIONS: ML models combining ECG time-series features and clinical variables were able to predict non-arrhythmic mortality within three years after device implantation in a primary prevention population, with robust performance in an independent cohort.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Seleção de Pacientes , Volume Sistólico , Função Ventricular Esquerda , Aprendizado de Máquina , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Prevenção Primária
8.
N Engl J Med ; 389(11): 1056-1057, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37703567
9.
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37767710

RESUMO

BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Ovinos , Animais , Lipopolissacarídeos , Carneiro Doméstico , Ventrículos do Coração , Desenho de Equipamento
10.
Heart Rhythm ; 20(12): 1649-1656, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37579867

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) delivers 80 J shocks from an 8 cm left-parasternal coil to a 59 cm3 left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggested that a second shock coil either parallel to the left-parasternal coil or transverse from the xiphoid to the PG pocket would significantly reduce the defibrillation threshold. OBJECTIVE: The purpose of this study was to acutely assess the defibrillation efficacy of parallel and transverse configurations in patients receiving an S-ICD. METHODS: Testing was performed in patients receiving a conventional S-ICD system. Success at 65 J was required before investigational testing. A second electrode was temporarily inserted from the xiphoid incision connected to the PG with an investigational Y-adapter. Phase 1 (n = 11) tested the parallel configuration. Phase 2 (n = 21) tested both parallel and transverse configurations in random order. RESULTS: This study enrolled 35 patients (28 males (80%); mean age 51 ± 17 years; left ventricular ejection fraction 40% ± 15%; body mass index 26 ± 4 kg/m2; prior myocardial infarction 46%; congestive heart failure 49%; cardiomyopathy 63%). Compared to the conventional S-ICD system, mean shock impedance decreased for both parallel (69 ± 15 Ω vs 86 ± 20 Ω; n = 33; P < .001) and transverse (56 ± 14 Ω vs 81 ± 21 Ω; n = 20; P < .001) configurations. Shock success rates at 20, 30, and 40 J were 55%, 79%, 97%, and 25%, 70%, 90% for parallel and transverse configurations, respectively. Defibrillation threshold testing was well tolerated with no serious adverse events. CONCLUSION: Adding a second shock coil, particularly in the parallel configuration, significantly reduced the impedance and had a high likelihood of defibrillation success at energies ≤40 J. This may enable the development of a smaller S-ICD.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Massa Corporal , Cardiomiopatias/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Volume Sistólico , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda
11.
Circ Arrhythm Electrophysiol ; 16(8): 421-432, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37582163

RESUMO

BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.


Assuntos
Desfibriladores Implantáveis , Humanos , Fibrilação Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
12.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

13.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37379530

RESUMO

AIMS: After implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD), a defibrillation test (DFT) is performed to ensure that the device can effectively detect and terminate the induced ventricular arrhythmia. Data on DFT efficacy at generator replacement are scarce with a limited number of patients and conflicting results. This study evaluates conversion efficacy during DFT at elective S-ICD generator replacement in a large cohort from our tertiary centre. METHODS AND RESULTS: Retrospective data of patients who underwent an S-ICD generator replacement for battery depletion with subsequent DFT between February 2015 and June 2022 were collected. Defibrillation test data were collected from both implant and replacement procedures. PRAETORIAN scores at implant were calculated. Defibrillation test was defined unsuccessful when two conversions at 65 J failed. A total of 121 patients were included. The defibrillation test was successful in 95% after the first and 98% after two consecutive tests. This was comparable with success rates at implant, despite a significant rise in shock impedance (73 ± 23 vs. 83 ± 24 Ω, P < 0.001). Both patients with an unsuccessful DFT at 65 J successfully converted with 80 J. CONCLUSION: This study shows a high DFT conversion rate at elective S-ICD generator replacement, which is comparable to conversion rates at implant, despite a rise in shock impedance. Evaluating device position before generator replacement may be recommended to optimize defibrillation success at generator replacement.


Assuntos
Desfibriladores Implantáveis , Humanos , Estudos Retrospectivos , Arritmias Cardíacas , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia
14.
J Cardiovasc Electrophysiol ; 34(7): 1561-1568, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37330678

RESUMO

INTRODUCTION: Transvenous implantable cardioverter-defibrillator (ICD) shocks have been associated with cardiac biomarker elevations and are thought in some cases to contribute to adverse clinical outcomes and mortality, possibly from myocardium exposed to excessive shock voltage gradients. Currently, there are only limited data for comparison with subcutaneous ICDs. We sought to compare ventricular myocardium voltage gradients resulting from transvenous (TV) and subcutaneous defibrillator (S-ICD) shocks to assess their risk of myocardial damage. METHODS: A finite element model was derived from thoracic magnetic resonance imaging (MRI). Voltage gradients were modeled for an S-ICD with a left-sided parasternal coil and a left-sided TV-ICD with a mid-cavity, a septal right ventricle (RV) coil, or a dual coil lead (TV mid, TV septal, TV septal + superior vena cava [SVC]). High gradients were defined as > 100 V/cm. RESULTS: The volumes of ventricular myocardium with high gradients > 100 V/cm were 0.02, 2.4, 7.7, and 0 cc for TV mid, TV septal, TV septal + SVC, and S-ICD, respectively. CONCLUSION: Our models suggest that S-ICD shocks produce more uniform gradients in the myocardium, with less exposure to potentially damaging electrical fields, compared to TV-ICDs. Dual coil TV leads yield higher gradients, as does closer proximity of the shock coil to the myocardium.


Assuntos
Desfibriladores Implantáveis , Veia Cava Superior , Humanos , Ventrículos do Coração , Miocárdio , Tela Subcutânea/diagnóstico por imagem
16.
Heart Rhythm ; 20(8): 1128-1135, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37271354

RESUMO

BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing. OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort. METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit. RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%). CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.


Assuntos
Marca-Passo Artificial , Humanos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/terapia , Resultado do Tratamento , Estudos Retrospectivos , Lipopolissacarídeos , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversos
17.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37212442

RESUMO

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Assuntos
Arritmias Cardíacas , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Seguimentos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/terapia
18.
Heart Rhythm ; 20(8): 1146-1155, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075958

RESUMO

BACKGROUND: Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE: The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2i™) communication methodology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS: RA and RV LPs were implanted and paired in 7 ovine subjects (4 with induced complete heart block). AV synchrony (% AV intervals <300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diagnostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postimplant (final i2i evaluation period: week 16-23). RESULTS: Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i evaluation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION: Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Animais , Ovinos , Estimulação Cardíaca Artificial/métodos , Lipopolissacarídeos , Bloqueio Atrioventricular/terapia , Frequência Cardíaca
19.
Heart Lung Circ ; 32(5): 629-637, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36990960

RESUMO

BACKGROUND: Bradyarrhythmias are adequately treated with pacemakers. There are different pacing modes (single-chamber, dual-chamber, cardiac resynchronisation therapy [CRT] and conduction system pacing [CSP]) and a choice between leadless or transvenous pacemakers. The expected pacing need is important for determining optimal pacing mode and device type. This study aimed to evaluate atrial pacing (AP) and ventricular pacing (VP) percentages over time for the most common pacing indications. METHODS: Included patients were aged ≥18 years with a dual-chamber rate-modulated [DDD(R)] pacemaker implantation and ≥1 year of follow-up at a tertiary centre between January 2008 and January 2020. Baseline characteristics, AP and VP at yearly follow-up visits up to 6 years after implantation were retrieved from the medical records. RESULTS: A total of 381 patients were included. Primary pacing indications were incomplete atrioventricular block (AVB) in 85 (22%), complete AVB in 156 (41%) and sinus node dysfunction (SND) in 140 (37%) patients. Mean age at implantation was 71±14, 69±17 and 68±14 years, respectively (p=0.23). Median follow-up was 42 months (25-68 months). Overall, AP was highest in SND with median 37% (7%-75%) versus 7% (1%-26%) in incomplete AVB and 3% (1%-16%) in complete AVB (p<0.001); VP was highest in complete AVB with median 98% (43%-100%) versus 44% (7%-94%) in incomplete AVB and 3% (1%-14%) in SND (p<0.001). Ventricular pacing significantly increased over time in patients with incomplete AVB and SND (both p=0.001). CONCLUSIONS: These results confirm the pathophysiology of different pacing indications, causing clear differences in pacing need and expected battery longevity. They may help guide optimal pacing mode and suitability for leadless or physiological pacing.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Marca-Passo Artificial , Humanos , Adolescente , Adulto , Estimulação Cardíaca Artificial/métodos , Átrios do Coração , Síndrome do Nó Sinusal
20.
Neth Heart J ; 31(5): 181-184, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36862338

RESUMO

Cardiac implantable electronic device (CIED) therapy is an essential element in treating cardiac arrhythmias. Despite their benefits, conventional transvenous CIEDs are associated with a significant risk of mainly pocket- and lead-related complications. To overcome these complications, extravascular devices (EVDs), such as the subcutaneous implantable cardioverter-defibrillator and intracardiac leadless pacemaker, have been developed. In the near future, several other innovative EVDs will become available. However, it is difficult to evaluate EVDs in large studies because of high costs, lack of long-term follow-up, imprecise data or selected patient populations. To improve evaluation of these technologies, real-world, large-scale, long-term data are of utmost importance. A Dutch registry-based study seems to be a unique possibility for this goal due to early involvement of Dutch hospitals in novel CIEDs and an existing quality control infrastructure, the Netherlands Heart Registration (NHR). Therefore, we will soon start the Netherlands-ExtraVascular Device Registry (NL-EVDR), a Dutch nationwide registry with long-term follow-up of EVDs. The NL-EVDR will be incorporated in NHR's device registry. Additional EVD-specific variables will be collected both retrospectively and prospectively. Hence, combining Dutch EVD data will provide highly relevant information on safety and efficacy. As a first step, a pilot project has started in selected centres in October 2022 to optimise data collection.